TM 9-2350-277-34
VEHICLE WILL NOT ACCEPT EXTERNAL AC POWER (M1068A3 ONLY) — Continued
0008 00
8Y
1.
Install XK2 relay (1) in relay socket (2) and secure
with relay bail (3).
2.
Apply external source of AC power to SICPS vehicle.
See TM 11-7010-256-12&P.
3.
Measure voltage between K3 relay terminal A2 (4) and
terminal block E4 post 1 (5).
4.
Does multimeter read 110 volts AC or for each measurement?
8YN
1.
Replace K3 relay (WP 0091 00).
2.
Verify no faults found.
0008 00-10
Change 4