TM-9-2350-277-34

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

  TM-9-2350-277-34 - Page 839 of 871

TM 9-2350-277-34
FABRICATED TOOLS — Continued
0121 00
PARTS REQUIRED
W3 Cable P/N 12383899
Plug WC596-13-3 or WC596/100-1
NOTES
1. Remove connector labeled W3P1 (A3J1) from W3 Cable.
2. Cut cable to required length (for connecting Power Control Enclosure to AC outlet).
WARNING
Incorrect polarity can harm personnel and damage equipment when power is applied to the Power Control
Enclosure. Make sure polarity is correct when installing plug on cable.
3. Install new plug WC596-13-3 or WC596/100-1 on W3 cable. Connect per wiring diagram.
4. Purpose of cable is to connect the Power Control Enclosure to shop AC power.
Special Purpose Power Cable for Power Control Enclosure (M1068A3 Only)
0121 00-2
Change 4


Back to Top