TM 9-2350-311-10
Item
No.
72
Interval
Weekly
Table 2-1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES
FOR M109 SELF-PROPELLED HOWITZER - CONTINUED
Location
Item to Check/
Service
NBC System
M 109A4/M109A5)
Crewmember
Procedure
CHIEF OF SECTION AND CREW
WARNING
NBC contaminated filters must be handled us-
ing adequate precautions and must be dis-
posed of by trained personnel.
a. Open spring clip (1) on M2A2 air purifier (2).
Turn NBC switch (3) on driver’s fixed instrument
panel (4) to ON position. Ensure NBC indicator
light (5) lights. Place switch (6) on NBC control
box assembly (7) to ON position. Ensure indica-
tor light (8) lights.
b. Inspect hoses for leaks, splits, and abrasions.
c. Connect M25A1 masks to all six stations and
check that air is entering all M25A1 masks.
Not Fully Mission
Capable If:
Change 2 2-85