TM 9-2350-311-10
2-10 OPERATING PROCEDURES
2–10.1 Starting Procedures
a. Starting Engine
1
2
3
4
Do not operate engine of vehicle in an enclosed area unless it is adequately ventilated.
Do not leave driver’s compartment, except during firing, with engine running. Personnel
injury could result.
Press down on brake pedal (1), pull out and down on manual control handle (2) and then release manual
control handle to set parking brake.
Shift transmission shift control lever (3) into N (neutral) position.
Turn MASTER switch (4) to ON. MASTER indicator light (5) will illuminate.
Pull out FUEL SHUT OFF control assembly handle (6) to off position before checking for hydrostatic
lock.
2-95