TM 9--2350--311--10
2--140
Change 6
2--11 OPERATION OF FIRE CONTROL EQUIPMENT UNDER NORMAL CONDITIONS
— CONTINUED
2--11.1
M117/M117A2 Panoramic Telescope and M145/M145A1 Telescope Mount — Continued
d. Quick Alinement of M117/M117A2 Panoramic Telescope Using the M140/M140A1 Alinement Device
— Continued
NOTE
Ensure mounting surfaces are clean and free of burrs. If dovetail door wedge has burrs, notify
unit maintenance.
2
Driver slips M140/M140A1 alinement device (28) onto dovetail door wedge (29) in front of panoramic
telescope ballistic cover (30) and secures in position by turning clamping catch (31). Ensure
M140/M140A1 alinement device is securely latched.
2.1
If using ERLS version, depress button (31.1) to activate.
3
To rotate panoramic telescope ballistic cover (30), release brakes using rod end clevis assemblies (32)
inside cab and rotate by holding webbing straps (33).
4
Sighting through M117/M117A2 panoramic telescope (1) eyepiece at M140/M140A1 alinement device
(28), line up apertures as shown. At this setting, M117/M117 panoramic telescope is in close alinement
with cannon tube.
5
Driver should release clamping catch (31) and remove M140/M140A1 alinement device (28) from
dovetail door wedge (29) and hand it to gunner for stowage.


Back to Top