2–20 OPERATION IN UNUSUAL ENVIRONMENT/WEATHER — CONTINUED
2-20.4 Operation in Extreme Cold — Continued
d. Cold Weather Starting (Vehicles with Engine Model 7083-7396) — Continued
Combat override switch in M109A4 and M109A5 howitzers should be used in emergencies only,
as determined by section chief. STARTER control switch must never be engaged for more than
2 minutes at a time. Do not make more than two attempts to start engine using combat override
switch as damage to starter or low battery voltage may occur.
NOTE
• To assist in starting, hand throttle control lever setting may be increased 1/8 travel when
engine speed exceeds 500 rpm.
• If engine does not start after 2 minutes of cranking, wait at least 2 minutes before trying to
start again. If engine does not start after two tries, stop starting procedure and notify unit
maintenance.
• If engine does not reach 100 rpm or more after 15 seconds, notify unit maintenance.
8 If engine in M109A4 or M109A5 howitzer does not start, repeat step 7 while engaging both STARTER
control switch (14) and combat override switch (16). If engine does not start after two attempts, stop
starting procedures and notify unit maintenance.
2-278