5-22 STOWAGE OF PROJECTILE EXTRACTOR IN HOWITZER
Stow the projectile extractor (1) in the holding brackets (2) provided. Due to space limitations, the projectile extractor
must be stowed in the retracted position. See paragraph 5-18 for projectile extractor breakdown procedures.
5-23 M712 PROJECTILE MAINTENANCE
Humidity indicators on containerized M712 projectiles must be monitored for humidity every 90 days, as a minimum. If
relative humidity in the container is 40 percent or greater, (40 percent section of humidity indicator card is not blue), turn
containerized M712 projectile in to battalion ammunition section.