TM-9-2350-311-20-1

HOWITZER, MEDIUM, SELF-PROPELLED, 155MM; M109A2, M109A3, M109A4 AND M109A5

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL FOR HULL, POWERPLANT, DRIVE CONTROLS, TRACKS, SUSPENSION, AND ASSOCIATED COMPONENTS

AUGUST 1994

  TM-9-2350-311-20-1 - Page 232 of 1275

TM 9-2350-311-20-1
3-3 TROUBLESHOOTING CHART — CONTINUED
j.
MASTER WARNING LIGHT (STEERING SHAFT) (1) MASTER WARNING LIGHT (STEERING SHAFT
CIRCUIT — CONTINUED
FAILS TO OPERATE; OTHER MASTER WARNING
LIGHT(S) OPERATE PROPERLY — CONTINUED
Repair or replace lead 27 of
bulkhead-to-portable instrument
panel wiring harness (para 8-49).
Replace circuit breaker (para 8-33,
Troubleshoot master relay circuit (para
3-3b).
END OF TASK
3-132
M109A2/M109A3; para 8-34, M109A4/
M109A5).