TM 9-2510-247-13&P
0057 00
REMOVAL OF PRIMARY MOTOR - Continued
NOTE
There are two hydraulic motors - primary (3) and isolated (11).
The solenoid to primary motor wire must be removed from primary motor prior to removal.
1. Loosen two mounting bolts (1).
2. Remove solenoid to motor wire (2) from primary motor (3).
3. Disconnect hose from elbow (4) on primary motor (3).
4. Disconnect two straight adapters (5).
5.
Remove two screws (6), lockwashers (7), and flatwashers (8) from bracket (9) on primary
motor (3). Discard lockwashers.
6.
Loosen two screws (10) and remove primary motor (3) from bracket.
Figure 105.
Hydraulic Motor Assembly