2-5. SOLENOID TESTING PROCEDURES (Continued)
Location/Item
Action
1. Disconnect solenoid wire leads of solenoid(s) to be checked from
subject symptom.
Solenoid identification is stamped on the
harness lead connector.
TM85312
2 Measure resistance
through each subject
solenoid wire con-
nector to ground
connector location
60-80 ohms means solenoid is good. If solenoid
resistance is not within limits, replace solenoid
in accodance with para. 4-31.
TM85313
3. After checking solenoid(s) identified in troubleshooting step? use test
results in the next block of instruction in the troubleshooting malfunction
sequence
2-16
Para. 2-5