TM 9-2920-225-34
d.
Cleaning. There are no special cleaning procedures needed. Refer to
cleaning procedures given in para 1-3.
e. Inspection and Repair.
(1) Inspection.
1.
2.
3.
4.
5.
6.
7.
Measure
Measure
Measure
Measure
Measure
Measure
Measure
NOTE
Readings for rotor (1) and drive end bell (2) must be
within limits given in table 2-4. If readings are not
within given limits, generator is nonrepairable.
outside diameter of sliprings (3).
outside diameter of slipring end of shaft (4).
outside diameter of drive end of shaft bearing seat (5).
outside diameter of drive end of shaft (6).
inside diameter of drive end bell bearing bore (7).
NOTE
If bearing (8) is not within limits given in table 2-4,
get a new bearing.
outside diameter (9) of drive end bearing (8).
inside diameter (10) of drive end bearing (8).
GO TO FRAME 2
TA 103587
2-87