TM-9-2920-225-34

GENERATOR ASSEMBLY; PRESTOLITE AMA-5102UT; LEECE-NEVILLE 3002AC, 3002AD, 3002AE, 5504AA, 5504AB, 2184AC, 5300GP

TECHNICAL MANUAL; MAINTENANCE; DIRECT AND GENERAL SUPPORT LEVEL

FEBRUARY 1981

  TM-9-2920-225-34 - Page 177 of 262

TM 9-2920-225-34
d. Cleaning.
There are no special cleaning procedures needed. Refer to
cleaning procedures given in para 1–3.
e. Inspection and Repair.
1.
2.
3.
4.
5.
NOTE
Readings must be within limits given in table 2-5. If
readings are not within given limits, generator is non-
repairable.
Check that end housing (1) and bearing retainers (2 and 3) have no cracks
or breaks. If parts are damaged, generator is nonrepairable.
Measure end housing bearing bore (4).
Check that screws (5) are not bent or broken and that they have no stripped
threads or damaged heads. If screws are damaged, get new ones.
Measure bearing (6) inside diameter (7) and outside diameter (8). If inside
and outside diameters are not within limits given in table 2-5, get new
bearing.
Check that bearing (6) is not damaged. Refer to TM 9-214.
GO TO FRAME 2
Table 2-5. End Housing Assembly Wear Limits
Index
Number
4
7
8
Item /Point of Measurement
Inside diameter of end housing
bearing bore
Inside diameter of end housing
bearing
Outside diameter of end housing
bearing
Size and Fit
of New Parts
(inches)
1.8497 to 1.8501
0.7870 to 0.7874
1.8499 to 1.8504
Wear Limits
(inches)
None
None
None
2-161


Back to Top