PS Magazine - TB 43-PS-606

PS, The Preventative Maintenance Monthly

ISSUE 606

MAY 2003

PS Magazine - TB 43-PS-606 - Page 13 of 32
PS 606
MAY 03
22
M1068 Command Post Carrier…
Move Table to
Stop Harness Damage
The M1068 command post
carrier's workstation table
damages the wiring harness
on the tent interface panel
when the table's in the
down position.
So you need
to move that
table. Here's
how…
2.
Remove the 2 hex-head
bolts, washers and nuts.
5.
Move the table
top 1 inch to the
right on the
mounting bracket.
9.
Install the 2 hex-head
bolts, washers, nuts and
tension spring.
3.
Remove the table from the workstation.
4.
Remove the 6 self-tapping screws.
6.
Mark and tap the new location
for the 6 self-tapping screws.
8.
Re-mount the table to the workstation.
The table should
be flush with the
mounting bracket.
7.
Secure the table to the mounting bracket.
1.
With the table in
the down position,
remove the tension
spring.


Back to Top