9. Install a 3/8" plastic tube between the bottom porT of the
reservoir and the bottom port of the air dryer± ²he tube
should be jUst long enough to make the connection
(there should be no undue stress or kinks)³
If a new heavy duty canister is being installed, continUe
with ´nstallat´on instructions. µf not¶ stop here and go
to the operat·onal checks³
Inspect¸on of the existing
canister and coalescing filter ´s recommended ¸f they
are to remain installed¹
10º Loosen desiccant canister with a strap wrench at the
base of the canister and sp´n ofF by hand. (O»C #7206
Snap-On #A91 C or equivalent.)
11º Remove the coalesc¸ng filter and inspect for damage¶
deterioration and/or excessive contamination. Replace
filter if necessary³ (¼se Coalescing ½ilter Kit ¾¿6021³À
Á2. Âf the coalescÃng fiÄter is replaced, instalÄ the new filter in
accordance with the instructions furnished with the kitº
Lubricate alÄ ÅOÆ-Rings and seals with siÄicone grease
prior to assembly³
13± Remove the existing ÇÈÉÊ-Ring from the canister mounting
nipple and apply the new one provided in the Heavy Duty
Kit.
14± Apply anti-seize compound to the threads of the adapter
n´pple.
15³ Install the new heavy duty desiccant canister and tighten
by hand. Canister should turn 1 /4 to 3/4 turn past first
gasket contact±
Proceed to Operational Checks±