Remove
Connect
universal joints (refer to vehicle TM-20).
NOTE
When installing starter cable connector, be sure that pin
in position “A" (Ckt 920A) has not been pushed back into
grommet.
ground hop hardware (refer to vehicle TM-20).
Purge fuel/water separator (refer to vehicle TM-20).
Connect battery ground terminals (refer to vehicle TM-20).
Start engine and bring it up cooperating temperature.
Run engine up to 1600 RPM and turn smoke
white smoke should emit from both exhaust stacks.
procedures in paragraph ll or vehicle TM-20.
i. While smoke system is operating, inspect fuel
j.
Shut smoke switch OFF,
engine OFF.
k.
1.
m.
n.
o.
a.
Disconnect battery ground
generator switch ON. A dense cloud of
If it does not, refer to troubleshooting
line connections for leaks.
run engine about a minute to purge exhaust and shut
terminals.
Remove groundhog hardware (refer to vehicle TM-20).
Install universal joints (refer to vehicle TM-20).
Install power plant (refer to vehicle TM-20).
Operate smoke system after power plant is installed to be sure system is operationaL
Troubleshoot according to Section VIII.
Section VIII. Troubleshooting
Vehicle fails to make smoke when engine is running and smoke generator is activated.
(1) Insure shut-off valve is open.
(2) Insure blower motor switch is on (M60A1-RISE and M60A3 only).
(3) Bring engine speed to 1000 rpm momentarily to insure generator output.
Generator output is necessary to close the air cleaner blower motor relay which provides power
to the air cleaner blower motors and the smoke generator solenoids. If air cleaner blower
motors are not operating, check generator output.
(4) Check for fuel running out of hull drains, indicating a ruptured fuel hose of loose
connection.
(5) Check solenoid valves.
With engine running, have someone turn smoke generator
switch on and off. Feel valves to see if they are activated. Check for voltage at valves and
good ground connection.
The solenoid valves can also be checked without releasing fuel into the
exhaust pipes by closing the shut-off valve.