MWO-9-2350-314-20-9

MODIFICATION OF HOWITZER, MEDIUM, SELF-PROPELLED: 155MM, M109A6

MODIFICATION WORK ORDER

OCTOBER 1997

  MWO-9-2350-314-20-9 - Page 5 of 10

MWO 9-2350-314-20-9
b.
Installation of New Loop Clamps and New Mounting Plate
(1) Fasten mounting plate (13) to the hydraulic compartment wall with two screws
(10), two new lockwashers (11), and two flat washers (12).
(2) Open each loop clamp (14) by removing nut (15).
(3) Guide loop clamps (14) through mounting plate (13)
(4) Position the pulse accumulator (3) in place on mounting plate (13).
(5) Fasten each loop clamp (14) around the pulse accumulator (3) with nut (15).
Tighten the nut on each loop clamp.
(6) Service pulse accumulator (3) IAW TM 9-2350-314-20-2-2, paragraph 28-12.
(7) Reconnect the battery ground leads.
(8) Recharge the hydraulic system IAW TM 9-2350-314-20-2-2, paragraph 18-l.
5