TB 9-2300-378-14
4-13. Air Cleaner Housing Vertical Guide Rework.
a.
General.
Misalignment between the air cleaner housing vertical guide bar and filter element
locating pin causes an improper filter seal.
To correct this problem the following
procedure must be performed.
b. Procedure.
(1) Tools and Equipment Required:
(a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(i)
(j)
(k)
(l)
Grinding Wheel -
2" x 1/2", 18500 RPM min for 3/8" arbor.
Cut-off Wheel - 2" x 1/8", 18500 RPM min for 3/8" arbor.
Scribe
Scale or Ruler
Masking Tape
Cardboard
Rags
Approved Eye Protection
(2) Fabricate template (fig. 4-27).
NOTE
Template can be fabricated to simplify measurement and
scribing of guide bar.
Rework procedure can be accomplished without template by
measuring directly on guide bar.
(3) Remove air cleaner filter element (TM-20).
NOTE
If template was fabricated, go to step (4). If template was
not fabricated, go to step (5).
(4) Position template on air cleaner housing and scribe left and right vertical guide
bars as indicated (view A). Go to step (6).
4-51