TB 9-2320-279-13-1
0020-1
0020
AC ALTERNATOR AND PULLEY REPLACEMENT
DRAFT
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
REMOVAL
NOTE
Tag and mark wires prior to removal to ensure proper installation.
1. Remove nut (1), lockwasher (2), and two wires (3 and 4) from terminal (5).
2. Remove nut (6), lockwasher (7), and wire (8) from terminal (9).
3. Remove nut (10), lockwasher (11), and two wires (12 and 13) from terminal (14).
THIS WORK PACKAGE (WP) COVERS:
Removal
Installation
Follow-On Maintenance
INITIAL SETUP:
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HEMAC001
Maintenance Level
Field Level Maintenance
Equipment Condition
Batteries disconnected (TM 9-2320-279-20).
Left splash guard removed (TM 9-2320-279-20).
AC alternator drive belts removed (WP 0019).
Tools and Special Tools
Shop Equipment, Common No. 1 (Item 4,
Appendix F)
Shop Equipment, Common No. 2 (Item 5,
Appendix F)
Tool Kit, General Mechanic’s (Item 7, Appendix F)
Materials/Parts
Sealant, RTV200 Electrical (Item 6, Appendix E)
Tags, Identification (Item 9, Appendix E)
Personnel Required
MOS 52C, Utilities equipment repairer (2)
References
TM 9-2320-279-20