AC FAN CONTROL SWITCH REPLACEMENT
DRAFT
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
REMOVAL
1. Loosen two screws (1) and remove knob (2) from fan control switch (3).
NOTE
Note position of fan control switch prior to removal to ensure proper installation.
2. Remove nut (4) and fan control switch (3) from center cover (5).
THIS WORK PACKAGE (WP) COVERS:
Removal
Installation
Follow-On Maintenance
INITIAL SETUP:
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HEMAC045
Maintenance Level
Field Level Maintenance
Equipment Condition
Batteries disconnected (TM 9-2320-279-20).
AC heater/evaporator cover removed (WP 0037).
Tools and Special Tools
Goggles (Item 1, Appendix F)
Tool Kit, General Mechanic’s (Item 7, Appendix F)
Materials/Parts
Solvent, Dry Cleaning (Item 8, Appendix E)
Tags, Identification (Item 9, Appendix E)
Personnel Required
MOS 52C, Utilities equipment repairer
References
TM 9-2320-279-20