TB 9-2320-279-13-1
0040-5
AC HOSES REPLACEMENT - Continued
DRAFT
HOSE ASSEMBLY #6 2524 INSTALLATION
NOTE
•
Refer to Appendix A, Figure A-2, for routing and location of AC hoses.
•
Install cable ties as required.
•
Route AC hose as noted prior to removal.
•
Ensure preformed packings are in place in AC hose prior to installation.
1. Install preformed packing (24) and hose 2524 (1) on fitting (25).
Torque hose 2524 (1) to 11-13 ft-lbs.
(15-18 N•m).
2. Position hose 2524 (1) in cushion clip (22).
3. Install cushion clip (22) on bracket (23) with screw (21) and locknut (20).
HEMAC103
HEMAC102