0042-1
0042
AC LOWER PLENUM AND DAMPER REPLACEMENT
DRAFT
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
REMOVAL
NOTE
Note position of damper prior to removal to ensure proper installation.
1. Remove damper (1) from lower plenum (2).
2. Remove four cable ties (3) and lower plenum (2) from four defrost tubes (4).
THIS WORK PACKAGE (WP) COVERS:
Removal
Installation
Follow-On Maintenance
INITIAL SETUP:
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HEMAC060
Maintenance Level
Field Level Maintenance
Equipment Condition
AC heater/evaporator removed (WP 0038).
Tools and Special Tools
Tool Kit, General Mechanic’s (Item 7, Appendix F)
Materials/Parts
Adhesive, 3M #1300 (Item 1, Appendix E)
Ties, Cable (Item 12, Appendix E)
Personnel Required
MOS 52C, Utilities equipment repairer
References