TB-9-2320-279-13-1

TECHNICAL BULLETIN; AIR CONDITIONING SYSTEM

OPERATOR’S, UNIT AND DIRECT SUPPORT MAINTENANCE MANUAL, INSTALLATION INSTRUCTIONS, AND REPAIR PARTS AND SPECIAL TOOLS LISTS

DECEMBER 2005

  TB-9-2320-279-13-1 - Page 76 of 524

TB 9-2320-279-13-1
0011-8
AC HEATER/EVAPORATOR BLOWER DOES NOT OPERATE IN ALL SPEEDS
(LOW, MEDIUM, AND HIGH) - Continued
DRAFT
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
KNOWN INFO
Fan control switch, fan control switch
harness, and AC heater/evaporator blower
resistor harness connections OK.
AC heater/evaporator blower operates in at
least one speed.
AC heater/evaporator blower resistor harness
orange wire OK.
Fan control switch harness orange wire OK.
AC heater/evaporator blower resistor harness
brown wire OK.
Fan control switch harness brown wire OK.
POSSIBLE PROBLEMS
AC heater/evaporator blower resistor harness
red wire faulty.
Fan control switch harness red wire faulty.
AC heater/evaporator blower resistor faulty.
Fan control switch faulty.
6.
Are 22 to 28 vdc measured on
red wire at fan control switch
harness connector,
terminal 1, when fan control
switch is in the low speed
position?
Go to Step 8 of this
fault.
NO
YES
Read WARNING on
page 0011-9.
WARNING
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TEST OPTIONS
Voltage test.
Multimeter.
REASON FOR QUESTION
If 22 to 28 vdc are not
measured, AC heater/
evaporator blower will not
operate at low speed.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
KNOWN INFO
Fan control switch, fan control switch
harness, and AC heater/evaporator blower
resistor harness connections OK.
AC heater/evaporator blower operates in at
least one speed.
AC heater/evaporator blower resistor harness
orange wire OK.
Fan control switch harness orange wire OK.
AC heater/evaporator blower resistor harness
brown wire OK.
Fan control switch harness brown wire OK.
Fan control switch harness red wire OK.
Fan control switch OK.
POSSIBLE PROBLEMS
AC heater/evaporator blower resistor harness
red wire faulty.
AC heater/evaporator blower resistor faulty.
7.
Is continuity measured
across AC heater/evaporator
blower motor resistor
harness red wire?
Repair AC heater/
evaporator blower
motor resistor harness
red wire (see
Appendix A) or replace
AC heater/evaporator
blower motor resistor
harness (WP 0036).
Verify repair, go to
Step 15 of this fault.
NO
YES
Read WARNING on
page 0011-9.
WARNING
Replace AC heater/
evaporator blower motor
resistor (WP 0035).
Verify
repair, go to Step 15 of this
fault.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TEST OPTIONS
Continuity test.
Multimeter.
REASON FOR QUESTION
If continuity is measured, AC
heater/evaporator blower
motor resistor is faulty.
If
not, AC heater/evaporator
blower motor resistor
harness red wire is faulty.


Back to Top