TB 9-2320-279-13-1
0011-14
AC HEATER/EVAPORATOR BLOWER DOES NOT OPERATE IN ALL SPEEDS
(LOW, MEDIUM, AND HIGH) - Continued
DRAFT
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
KNOWN INFO
Fan control switch, fan control switch
harness, and AC heater/evaporator blower
resistor harness connections OK.
AC heater/evaporator blower operates in at
least one speed.
AC heater/evaporator blower resistor harness
brown wire OK.
Fan control switch harness brown wire OK.
AC heater/evaporator blower resistor harness
red wire OK.
Fan control switch harness red wire OK.
POSSIBLE PROBLEMS
AC heater/evaporator blower resistor harness
orange wire faulty.
Fan control switch harness orange wire faulty.
AC heater/evaporator blower resistor faulty.
Fan control switch faulty.
12.
Are 22 to 28 vdc measured on
orange wire at fan control
switch harness connector,
terminal 3, when fan control
switch is in the high speed
position?
Go to Step 14 of this
fault.
NO
YES
Read WARNING on
page 0011-15.
WARNING
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TEST OPTIONS
Voltage test.
Multimeter.
REASON FOR QUESTION
If 22 to 28 vdc is not
measured, AC heater/
evaporator blower will not
operate at high speed.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
KNOWN INFO
Fan control switch, fan control switch
harness, and AC heater/evaporator blower
resistor harness connections OK.
AC heater/evaporator blower operates in at
least one speed.
AC heater/evaporator blower resistor harness
brown wire OK.
Fan control switch harness brown wire OK.
AC heater/evaporator blower resistor harness
red wire OK.
Fan control switch harness red wire OK.
Fan control switch harness orange wire OK.
Fan control switch OK.
POSSIBLE PROBLEMS
AC heater/evaporator blower resistor harness
orange wire faulty.
AC heater/evaporator blower resistor faulty.
13.
Is continuity measured
across AC heater/evaporator
blower motor resistor
harness orange wire?
Repair AC heater/
evaporator blower
motor resistor harness
orange wire (see
Appendix A) or replace
AC heater/evaporator
blower motor resistor
harness (WP 0036).
Verify repair, go to
Step 15 of this fault.
NO
YES
Read WARNING on
page 0011-15.
WARNING
Replace AC heater/
evaporator blower motor
resistor (WP 0035).
Verify
repair, go to Step 15 of this
fault.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TEST OPTIONS
Continuity test.
Multimeter.
REASON FOR QUESTION
If continuity is measured, AC
heater/evaporator blower
motor resistor is faulty.
If
not, AC heater/evaporator
blower motor resistor
harness orange wire is
faulty.


Back to Top