TB-9-2320-279-13-P-3

TECHNICAL BULLETIN; TANKER ARMOR MODULE KIT

OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST AND INSTALLATION INSTRUCTIONS)

JANUARY 2007

  TB-9-2320-279-13-P-3 - Page 317 of 396

TB 9-2320-279-13&P
0040
0040-67
5. Pull out on V6 FUEL/DEFUEL CONTROL VALVE handle (7).
6. Remove HAV HAND ACTUATED CONTROL VALVE (8) and hoses (9) from pump module.
Filter-separator may contain 20 to 30 gallons (75 to 115 liters) of fuel.
HAV HAND ACTUATED CONTROL VALVE lever must be squeezed through step (25) for fuel to
drain.
7. Squeeze and hold lever (10).
8. Open V15 DRAIN VALVE (11).
Remove filter-separator elements
.
Continue with step 10 after fuel stops draining from primary pump and filter-separator.
10. Close V15 DRAIN VALVE (11).
11. Push MC MANUAL CONTROL EM VALVE lever (1) full forward and down to CLOSE position.


Back to Top