2-138
TB 9-2510-251-13
2-1.4
Installation of Air Conditioning Kit to M1025A2 with GSIE Add-on-Armor (Cont’d).
d. Install Refrigerant Hoses (Cont’d)
18
19
17
20
Figure 2-209.
Drier Connection
22
24
23
21
Figure 2-210.
Condenser Connection
(14)
Connect Condenser.
a. Lubricate O-ring and install #6 female straight fitting (21) to outlet (smaller) fitting on
condenser.
b. Lubricate O-ring and install #8 female straight fitting (22) to inlet (larger) fitting on
condenser.
c.
Trim ends of #6 hose from drier (23) and connect to right fitting.
d. Trim ends of #8 hose from compressor (24) and connect to right fitting.
(15)
Reinstall plywood panel on top of transmission tunnel by notching around drain hoses and
refrigerant lines.
(13)
Connect Drier.
a. Lubricate O-ring and install #6 male stainless tube (17) on drier outlet.
b. Lubricate O-ring and install #6 female 90° fitting (18) on drier inlet.
c.
Trim ends of #6 hose (19) to condenser and connect to inlet (female) fitting.
d. Trim ends of #6 hose (20) to evaporator and connect to outlet (male) fitting.
e. Tighten fittings.