TB-9-2510-251-13

TECHNICAL BULLETIN

OPERATOR AND FIELD MAINTENANCE; INSTALLATION MANUAL (INCLUDING REPAIR PARTS LIST); FOR ADD-ON-ARMOR (AoA) AIR CONDITIONING

AUGUST 2007

  TB-9-2510-251-13 - Page 144 of 624

2-128
TB 9-2510-251-13
2-1.4
Installation of Air Conditioning Kit to M1025A2 with GSIE Add-on-Armor (Cont’d).
b. Install Evaporator and Condenser (Cont’d)
37
36
39
38
39
38
Figure 2-197.
Support Brackets Removal
Figure 2-198.
Side Condenser Mount Plates Removal
40
40
Figure 2-199.
Condenser Mount Brackets
(30)
Remove two screws (36) and support brackets (37).
Discard support brackets (37).
(31)
Remove six screws (38) and side condenser mount plates (39).
Discard side condenser
mount plates (39).
(32) Install two condenser mount brackets (40) and secure with existing hardware.


Back to Top