TB-9-2510-251-13

TECHNICAL BULLETIN

OPERATOR AND FIELD MAINTENANCE; INSTALLATION MANUAL (INCLUDING REPAIR PARTS LIST); FOR ADD-ON-ARMOR (AoA) AIR CONDITIONING

AUGUST 2007

  TB-9-2510-251-13 - Page 140 of 624

2-124
TB 9-2510-251-13
2-1.4
Installation of Air Conditioning Kit to M1025A2 with GSIE Add-on-Armor (Cont’d).
b. Install Evaporator and Condenser (Cont’d)
(16)
Insert four new bolts (14), flat washers (15), and oversize washers (16) through lower
evaporator support bracket and armor plates.
Install flat washers (17) and locknuts (18)
and tighten snug.
18
17
15
16
14
Figure 2-190.
Lower Support Bracket


Back to Top