0019-7
Change 1
TB 9-3950-253-13&P
0019
ELECTRICAL SYSTEM – CONTINUED
5. NO STOWAGE FUNCTION (ERROR CODE 7) – CONTINUED.
Step 11.
Set battery disconnect switch and ignition switch to ON position.
a.
If error code is still displayed, set ignition switch and battery disconnect switch to OFF posi-
tion, and replace additional MUX box (WP 0029).
b.
If error code is not displayed, set ignition switch and battery disconnect switch to OFF posi-
tion, reconnect pins 1, 2, 3, and 4 to P2 in additional MUX box and proceed to Step 12.
Step 12.
Disconnect wires from positions 1, 2, 3, and 4 on P1 in stowage MUX box (control panel).
Step 13.
Set battery disconnect switch and ignition switch to ON position.
a.
If error code is still displayed, set ignition switch and battery disconnect switch to OFF posi-
tion, and replace CAN bus harness between additional MUX box and stowage MUX box
(WP 0029).
b.
If error code is not displayed, set ignition switch and battery disconnect switch to OFF posi-
tion, and replace stowage MUX box (control panel) (WP 0029).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
0.