TM-3-1040-279-12-P

GENERATOR SET, SMOKE, MECHANICAL: PULSE JET, M157 W/120 GAL FOG OIL TANK AND W/80 GAL FOG OIL TANK

TECHNICAL MANUAL; OPERATOR’S AND ORGANIZATIONAL MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST AND DEPOT MAINTENANCE REPAIR PARTS

MAY 1987

  TM-3-1040-279-12-P - Page 108 of 389

TM 3-1040-279-12&P
4-11 COVER ASSEMBLY (CONT).
d. Cable Assembly 5J1.
REMOVAL
1.
2.
3.
4.
5.
6.
7.
Remove equipment container (P. 4-68).
Disassemble cover assembly (P. 4-36).
Remove four screws (l), washers (2) and nuts (3) and remove cable assembly (4) from cover
assembly (5).
Remove eight screws (6) and washers (7) and remove equipment container panel (8).
Remove four screws (9), washers (10), and lockwashers (11) securing terminal bracket assembly
(12) to gain access to terminal bracket assembly.
Remove electrical connections of 5J1 from top terminals of terminal board (13). See smoke
generator wiring (P. 4-34).
Remove cable assembly (4) from equipment container (14).
INSTALLATION
1.
2.
3.
4.
5.
6.
7.
Install cable assembly (4) in equipment container (14) and attach electrical connections. See smoke
generator wiring (P. 4-34). Coat terminal board screw threads with sealing compound (Item 11A,
App E) before securing connections.
Position terminal bracket assembly (12) in equipment container (14) and secure terminal bracket
assembly (12) with four screws (9), washers (10) and lockwashers (11).
Secure cable assembly (4) to cover assembly (5) with four screws (l), washers (2) and nuts (3).
Make sure switches on terminal bracket are in OFF (down) position.
Position equipment container panel (8) on equipment container (14) and secure with eight screws
(6) and washers (7).
Reassemble cover assembly (P. 4-37).
Install equipment container (P. 4-69).
4-44
Change 2


Back to Top