TM-3-1040-279-12-P

GENERATOR SET, SMOKE, MECHANICAL: PULSE JET, M157 W/120 GAL FOG OIL TANK AND W/80 GAL FOG OIL TANK

TECHNICAL MANUAL; OPERATOR’S AND ORGANIZATIONAL MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST AND DEPOT MAINTENANCE REPAIR PARTS

MAY 1987

  TM-3-1040-279-12-P - Page 168 of 389

TM 3-1040-279-12&P
4-26 NOZZLE ASSEMBLY.
This task covers repair of Nozzle.
INITIAL SETUP
Tools
General Mechanic’s Automotive Tool Kit
SC 5180-90-CL-N26
Equipment Condition
Nozzle assembly removed from smoke gener-
ator (P. 4-22).
General Safety Instructions
Before performing any maintenance proce-
dures be sure circuit breaker CB1 is in OFF
position.
DISASSEMBLY
1. Remove three screws (1) and washers (2) and disassemble nozzle assembly (3).
2. Remove nozzle (4) from support assembly (5).
REASSEMBLY
1. Install nozzle (4) on support assembly (5).
2. Reassemble nozzle assembly (3) with three screws (1) and washers (2).
4-104
Change 3


Back to Top