TM3-1040-279-12&P
h. Sensing Element.
REMOVAL
NOT E
On M1059 vehicles, lower inboard armor
shield and remove smoke generator from
vehicle mount for access (TM 9-2350-261-
20-1).
1.
2.
3.
4.
5.
Remove safety wire (l).
Disconnect cable assembly (2) from sensing element (3).
Remove element nut (4) from element (3).
Turn three screws (5) on three element clamps (6) and remove sensing element (3) from element
clamps (6), and brackets (7).
Remove grommets (8) from sensing element (3). Replace grommets as required.
Change 2
4-31