TM-5-2350-262-20-3

ARMORED COMBAT EARTHMOVER (ACE), M9

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL; VOLUME 3 OF 3; HYDRAULIC TROUBLESHOOTING TEST PROCEDURES

  TM-5-2350-262-20-3 - Page 105 of 319

3-70
TM 5-2350-262-20-3
YES
NO
from block 7
To block 10
9
Verify problem is solved.
8
Perform main relief valve adjustment.
Is hydraulic pressure between 3,950-4,050 psi
(27,235-27925 kPa)?
NO
6
EJECTOR DOES NOT EXTEND OR RETRACT (CONTINUED)


Back to Top