TM-5-2350-262-20-3

ARMORED COMBAT EARTHMOVER (ACE), M9

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL; VOLUME 3 OF 3; HYDRAULIC TROUBLESHOOTING TEST PROCEDURES

  TM-5-2350-262-20-3 - Page 108 of 319

3-73
TM 5-2350-262-20-3
MAIN HYDRAULIC PUMP PRESSURE TEST
WARNING
Before performing any troubleshooting in bowl, move ejector
forward and disable it from hydraulic system. Failure to comply
may result in severe injury or death to personnel.
Ensure globe valve is fully opened prior to starting vehicle. A fully
or partially closed valve
will cause immediate high pressure.
Failure to comply may result in damage to equipment and injury to
personnel.
Disconnect tee (4) from 13R high pressure filter inlet port, install coupling tube (2), globe
valve (3), tee (4), and pressure measuring device (5) between HYDR FLTR-IN-13R hose
(6) and high-pressure filter inlet port 13R.
Have assistant start engine and allow to idle. Slowly close globe valve (3) until pressure
reaches 3,950-4,050 psi (27,235-27,925 kPa).
Open globe valve (3). Stop engine; relieve hydraulic pressure. Remove all test equipment
and connect hoses.
Refer to TM 5-2350-262-20-2
NOTE
Have suitable container ready to catch oil.


Back to Top