EJECTOR DOES NOT EXTEND OR RETRACT - Continued
T00920HDC
4
3
2
1
Figure 17.
Hydraulic Diagnostic Center (HDC) Control Box.
CONDITION/INDICATION
Is transducer T-2 hydraulic pressure between 1,950-2,050 psi (13,445-14,135 kPa)?
DECISION
YES - Go to Step (11).
NO - Go to Step (10).