EJECTOR DOES NOT EXTEND OR RETRACT - Continued
T00909HDC
3
2
1
Figure 24.
Hydraulic Diagnostic Center (HDC) Control Box.
CONDITION/INDICATION
Is ejector cylinder leaking internally?
DECISION
YES - Replace or repair ejector cylinder (TM 5-2350-262-20) if ejector moved forward, or replace solenoid valve
V1 on HDC primary manifold if ejector moved AFT (WP
0035).
NO - Replace solenoid valve V1 on HDC primary manifold (WP
0035).
END OF WORK PACKAGE
TM 5-2350-378-23&P
0011
0011-23/24 blank