TM-5-2350-378-23-P

ARMORED COMBAT EARTHMOVER (ACE), M9; HYDRAULIC DIAGNOSTIC CENTER

TECHNICAL MANUAL; FIELD MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST

JUNE 2012

  TM-5-2350-378-23-P - Page 195 of 644

FRONT CORNER (LEFT OR RIGHT) RAISES IN UNSPRUNG, BUT NOT SPRUNG MODE - Continued
T01109HDC
5
4
3
2
1
Figure 7.
Hydraulic Diagnostic Center (HDC) Control Box.
CONDITION/INDICATION
Is transducer T-7 (left) and T-8 (right) hydraulic pressure greater than 2,500 psi
(17,238 kPa)?
DECISION
YES - Go to Step (11).
NO - Go to Step (12).
STEP
11.
Check for blockage between inlet port 9 of forward manifold and port 9 of No. 1 actuator, and between left
main manifold and No. 1 actuator.
CONDITION/INDICATION
Is there blockage?
DECISION
YES - Clear blockage. Verify problem is solved.
NO - Verify problem with operator.
TM 5-2350-378-23&P
0013
0013-11


Back to Top