HYDRAULIC OIL OVERHEATS - Continued
g.
Using LINE UP or LINE DOWN button (Figure 2, Item 3), select V5 on HDC display (Figure 2, Item 2).
h.
Open V5 on HDC display (Figure 2, Item 2) by selecting CHANGE POSITION button (Figure 2, Item 4)
on HDC control box.
T01303HDC
5
4
3
2
1
Figure 2.
Hydraulic Diagnostic Center (HDC) Control Box.
i.
Stop engine; relieve hydraulic pressure.
CONDITION/INDICATION
Is transducer T-1 hydraulic pressure greater than 1,000 psi (6,894.757 kPa)?
DECISION
YES - Replace solenoid valve V19 on HDC primary manifold (WP
0035).
NO - Go to Step (3).
TM 5-2350-378-23&P
0015
0015-3


Back to Top