HYDRAULIC OIL OVERHEATS - Continued
7
T01349HDC
12
11
10
1
2
3
4
9
8
6
5
Figure 34.
Main Hydraulic Accumulator.
CONDITION/INDICATION
Is gas valve pressure 1,750-1,850 psi (12,066-12,756 kPa)?
DECISION
YES - Go to Step (27).
NO - Go to Step (28).
TM 5-2350-378-23&P
0015
0015-39