HYDRAULIC OIL OVERHEATS - Continued
l.
Manually open V23 (Figure 30, Item 1) on DCV bank.
1
T01345HDC
Figure 30.
Apron Relief Valve.
(1)
Using LINE UP or LINE DOWN button (Figure 31, Item 2), select V1 on HDC display
(Figure 31, Item 1).
(2)
Open V1 on HDC display (Figure 31, Item 1) by selecting CHANGE POSITION button
(Figure 31, Item 3) on HDC control box.
(3)
Using LINE UP or LINE DOWN button (Figure 31, Item 2), select V17 on HDC display
(Figure 31, Item 1).
(4)
Open V17 on HDC display (Figure 31, Item 1) by selecting CHANGE POSITION button
(Figure 31, Item 3) on HDC control box.