TM 5--2350--378--24&P
0007 00--20
ALL HYDRAULIC FUNCTIONS INOPERATIVE -- Continued
0007 00
NO
from block 11
YES
NO
14
Verify problem is solved.
15
Replace directional control valve bank
(TM 5--2350--262--20--2).
13
Perform 13L main pump relief valve adjust-
ment using the HDC.
Can hydraulic pressure be adjusted to
3,950--4,050 psi (27,235--27,925 kPa)?