0007 00--11
ALL HYDRAULIC FUNCTIONS INOPERATIVE -- Continued
0007 00
Figure 7. HDC Control Box
Figure 8. DCV Bank
MAIN HYDRAULIC PUMP TEST -- CONTINUED
Have assistant start engine and allow engine to idle (750--800 rpm). Slowly close right
main hydraulic pressure inhibit valve V21 (Figure 8, item 1), until transducer T--3
pressure on the HDC display (Figure 7, item 1) indicates 3,950--4,050 psi
(27,235--27,925 kPa).
Fully open right main hydraulic pressure inhibit valve V21 (Figure 8, item 1).
Stop engine; relieve hydraulic pressure.
Open ejector inhibit ball valve V23 (Figure 8, item 2) on the DCV bank. Using LINE UP
or LINE DOWN button (Figure 7, item 3), select V1 on the HDC display (Figure 7,
item 2). Open V1 on the HDC display (Figure 7, item 2) by selecting the CHANGE
POSITION button (Figure 7, item 4) on the HDC control box.