TM 5--2350--378--24&P
0007 00--5
ALL HYDRAULIC FUNCTIONS INOPERATIVE -- Continued
0007 00
Figure 3. Hydraulic Return Line Filter
OIL FLOW TEST
NOTE
Have suitable container ready to catch oil.
Stop engine; relieve hydraulic pressure. Disconnect HYDR FLTR--IN--7 hose (Figure 3,
item 2) from tee (Figure 3, item 3) at port 7 on hydraulic return line filter (Figure 3,
item 1). Cap tee (Figure 3, item 3).
While holding open end of hose (Figure 3, item 2) in container, have assistant start
engine. Check for free flow of hydraulic oil from hose (Figure 3, item 2).
Stop engine; relieve hydraulic pressure. Connect hose (Figure 3, item 2) to tee
(Figure 3, item 3).