TM-5-2350-378-24-P

HYDRAULIC DIAGNOSTIC CENTER (HDC) SUPPORTING ARMORED COMBAT EARTHMOVER (ACE), M9

TECHNICAL MANUAL; UNIT, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST

  TM-5-2350-378-24-P - Page 100 of 790

TM 5--2350--378--24&P
0007 00--7
ALL HYDRAULIC FUNCTIONS INOPERATIVE -- Continued
0007 00
Figure 4. Main Pump
MAIN PUMP SUCTION HOSE CHECK
WARNING
Do not work under vehicle unless hull is properly blocked or allowed
to settle on bump stops. Failure to comply may result in severe
injury or death to personnel.
NOTE
Have suitable container ready to catch oil.
Loosen, but do not disconnect, PUMP SUCT TUBE--#7 (Figure 4, item 1) from elbow
(Figure 4, item 3) on main hydraulic pump (Figure 4, item 2). Hydraulic oil should flow
freely from the loosened fitting.


Back to Top