TM 5--2350--378--24&P
0009 00--13
APRON WILL NOT RAISE -- Continued
0009 00
Figure 9. Apron Control Valve
Figure 10. HDC Control Box
Figure 11. DCV Bank
CIRCUIT 19 RELIEF VALVE ADJUSTMENT -- CONTINUED
When transducer T--1 hydraulic pressure on the HDC display (Figure 10,
item 1) indicates 3,500 psi (24,131 kPa); tighten jam nut (Figure 9, item 1).
Stop engine; relieve hydraulic pressure.
Manually open ejector inhibit ball valve V23 (Figure 11, item 1) on the DCV bank. Using
LINE UP or LINE DOWN button (Figure 10, item 3), select V1 on the HDC display
(Figure 10, item 2). Open V1 on the HDC display (Figure 10, item 2) by selecting the
CHANGE POSITION button (Figure 10, item 4) on the HDC control box. Select V17 on
the HDC display (Figure 10, item 2). Open V17 on the HDC display (Figure 10, item 2)
by selecting the CHANGE POSITION button (Figure 10, item 4) on the HDC control box.