TM-5-2350-378-24-P

HYDRAULIC DIAGNOSTIC CENTER (HDC) SUPPORTING ARMORED COMBAT EARTHMOVER (ACE), M9

TECHNICAL MANUAL; UNIT, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST

  TM-5-2350-378-24-P - Page 159 of 790

TM 5--2350--378--24&P
0010 00--6
BUMP STOPS INOPERATIVE -- Continued
0010 00
2
Perform mechanical binding
check.
Is bump stop cylinder jammed
or binding?
NO
YES
To block 5
4
Free bump stop or replace damaged components
(TM 5--2350--262--20--2).
NO
from block 1


Back to Top