TM 5--2350--378--24&P
0010 00--11
BUMP STOPS INOPERATIVE -- Continued
0010 00
Figure 6. HDC Control Box
LEFT AND RIGHT FORWARD MANIFOLD PRESSURE TEST
Reset all HDC solenoid valves by selecting the RESET VALVES button (Figure 6, item 5)
on the HDC control box.
Start engine.
For left forward manifold pressure, close left forward manifold valve. Using LINE UP or
LINE DOWN button (Figure 6, item 3), select V9 on the HDC display (Figure 6, item 2).
Close V9 on the HDC display (Figure 6, item 2), by selecting the CHANGE POSITION
button (Figure 6, item 4) on the HDC control box. Read transducer T--7 hydraulic
pressure on the HDC display (Figure 6, item 1).
For right forward manifold pressure, close right forward manifold valve. Using LINE UP
or LINE DOWN button (Figure 6, item 3), select V10 on the HDC display (Figure 6,
item 2). Close V10 on the HDC display (Figure 6, item 2), by selecting the CHANGE
POSITION button (Figure 6, item 4) on the HDC control box. Read transducer T--7
hydraulic pressure on the HDC display (Figure 6, item 1).
Stop engine and relieve hydraulic pressure.
Reset all HDC solenoid valves by selecting the RESET VALVES button (Figure 6, item 5)
on the HDC control box.