TM 5--2350--378--24&P
BUMP STOPS INOPERATIVE -- Continued
0010 00
Figure 9. HDC Control Box
LEFT AND RIGHT FORWARD MANIFOLD PRESSURE TEST
Reset all HDC solenoid valves by selecting the RESET VALVES button (Figure 9, item 5)
on the HDC control box.
Have assistant start engine and move SPRUNG/UNSPRUNG lever to UNSPRUNG.
For left forward manifold pressure; Using LINE UP or LINE DOWN button (Figure 9, item
3), select V9 on the HDC display (Figure 9, item 2). Close V9 on the HDC display
(Figure 9, item 2), by selecting the CHANGE POSITION button (Figure 9, item 4) on the
HDC control box. Read transducer T--10 hydraulic pressure on the HDC display
(Figure 9, item 1).
For right forward manifold pressure; Using LINE UP or LINE DOWN button (Figure 9,
item 3), select V10 on the HDC display (Figure 9,
item 2). Close V10 on the HDC display (Figure 9, item 2), by selecting the CHANGE
POSITION button (Figure 9, item 4) on the HDC control box. Read transducer T--11
hydraulic pressure on the HDC display (Figure 9, item 1).
Reset all HDC solenoid valves by selecting the RESET VALVES button (Figure 9, item 5)
on the HDC control box.
Stop engine and relieve hydraulic pressure.
END OF WORK PACKAGE
0010 00--17/18 blank