TM 5--2350--378--24&P
0011 00--8
EJECTOR CREEPS -- Continued
0011 00
7
Verify problem with operator.
NO
from block 4
NO
YES
6
Replace HDC system solenoid
valve V20 on primary manifold
(WP 0035 00).
5
Perform HDC system solenoid valve
V20 test.
Is solenoid valve V20 leaking?