EJECTOR CREEPS -- Continued
0011 00
Figure 4. HDC Control Box
Figure 5. DCV Bank
EJECTOR CONTROL VALVE LEAKAGE TEST
Reset all HDC solenoid valves by selecting the RESET VALVES button (Figure 4, item 5)
on the HDC control box.
Disable ejector by manually closing the ejector inhibit ball valve V23 (Figure 5, item 1) on
the DCV bank. Using LINE UP or LINE DOWN button (Figure 4, item 3), select V1 on
the HDC display (Figure 4, item 2). Close V1 on the HDC display (Figure 4, item 2), by
selecting the CHANGE POSITION button (Figure 4, item 4) on the HDC control box.
Select V12 on the HDC display (Figure 4, item 2). Close V12 on the HDC display
(Figure 4, item 2), by selecting the CHANGE POSITION button (Figure 4, item 4) on the
HDC control box. Select V20 on the HDC display (Figure 4, item 2). Open V20 on the
HDC display (Figure 4, item 2), by selecting the CHANGE POSITION button (Figure 4,
item 4) on the HDC control box. Select V13 on the HDC display (Figure 4, item 2).
Close V13 on the HDC display (Figure 4, item 2) by selecting change position button
(Figure 4, item 4) on the HDC control box.
Start engine and hold EJECTOR CONTROL lever in the FORWARD or BACK position
until transducer T--2 hydraulic pressure on the HDC display (Figure 4, item 1) indicates
1,950--2,050 psi (13,445--14,135 kPa). Release EJECTOR CONTROL lever to the
NEUTRAL position, allow hydraulic pressure to stabilize for thirty seconds, then time the
pressure loss for one minute. If pressure loss is greater than 100 psi (690 kPa) per
minute, oil is leaking excessively past the ejector control valve spool.
Stop engine and relieve hydraulic pressure.
Enable ejector by manually opening the ejector inhibit ball valve V23 (Figure 5, item 1)
on the DCV bank.
Reset all HDC solenoid valves by selecting the RESET VALVES button (Figure 4, item 5)
on the HDC control box.