TM 5--2350--378--24&P
0011 00--11
EJECTOR CREEPS -- Continued
0011 00
Figure 7. HDC Control Box
Figure 8. DCV Bank
EJECTOR RELIEF VALVE TEST
Reset all HDC solenoid valves by selecting the RESET VALVES button (Figure 7, item 5)
on the HDC control box.
WARNING
S
Do not operate ejector when personnel are in bowl. Do not work in
bowl unless ejector lock is engaged. Failure to comply may result in
severe injury or death to personnel.
S
Do not stand or work in bowl area unless ejector lock is engaged. Do
not stand in bowl to observe roller guide travels. Failure to comply
may result in severe injury to personnel.
Disable ejector by manually closing the ejector inhibit ball valve V23 (Figure 8, item 1) on
the DCV bank. Using LINE UP or LINE DOWN button (Figure 7, item 3), select V1 on
the HDC display (Figure 7, item 2). Close V1 on the HDC display (Figure 7, item 2) by
selecting the CHANGE POSITION button (Figure 7, item 4) on the HDC control box.
Have assistant start engine and hold EJECTOR CONTROL lever in the FORWARD
position. Read transducer T--2 hydraulic pressure on the HDC display (Figure 7, item 1).
Stop engine; relieve hydraulic pressure.
Enable ejector by manually opening the ejector inhibit ball valve V23 (Figure 8, item 1)
on the DCV bank. Using LINE UP or LINE DOWN button (Figure 7, item 3), select V1 on
the HDC display (Figure 7, item 2). Open V1 on the HDC display (Figure 7, item 2) by
selecting the CHANGE POSITION button (Figure 7, item 4) on the HDC control box.